Chromatography Syringes
Syringes for manual or autosampler injections, in a variety of sizes, needle gauges, point styles, and terminations; includes electronic and manual gas tight syringes, HPLC general syringes, and replacement parts and accessories. Choose from leading brands for analytical gas and liquid syringes. Specialty syringes designed for unique applications are also available.
Filtered Search Results
Hamilton™ CTC and LEAP Technologies GC PAL Autosampler Syringes: Gastight
Designed for use in PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems
| For Use With (Equipment) | PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems |
|---|---|
| Product Type | Gastight Syringe |
| Quantity | Ea. |
| Min. Temperature (English) | 68°F |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 20°C |
Hamilton™ 700 Series Microliter™ 8100/8200 Autosampler Syringe
Syringe is designed to work with Bruker/Varian 8100/8200 autosamplers
Hamilton™ Microliter™ and Gastight™Model 7001 GC Syringes: For Agilent 7673, 7683, 7693 and 6850 ALS
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.049 in. |
| Length (Metric) | 43 mm |
| Volume (Metric) | 1 μL |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 1.24 mm |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 155°C |
| Max. Pressure | 6000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 7001 |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Hamilton™ Microliter™ and Gastight™ Syringes: Model 7000.5 for Agilent 7673, 7683, 7693 and 6850 ALS GC Syringes: Model 7000.5
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Needle Point Number | AS |
|---|---|
| Diameter (English) Inner | 0.049 in. |
| Length (Metric) | 43 mm |
| Length (English) | 1.7 in. |
| Diameter (Metric) Inner | 1.24 mm |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 155°C |
| Max. Pressure | 6000 psi |
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 6.6 mm |
| Connection Type | Removable |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Model | 7000.5 KH |
| Needle Point Style | Cone |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
Krackeler Scientific Straight Needles
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
| For Use With (Equipment) | Autosampler Syringe |
|---|---|
| Product Type | Straight Needle |
| Connection Type | Fixed |
| Needle Point Style | Cone |
| Quantity | 6 Pk. |
| Length (English) Needle | 1.65 in. |
| Needle Gauge | 23 G |
Krackeler Scientific Fixed-Needle Autosampler Syringes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Use one needle and get the benefits of two
| Product Type | Autosampler Syringe |
|---|---|
| Connection Type | Fixed |
| Needle Point Style | Tapered |
| Length (English) Needle | 1.65 in. |
| Needle Gauge | 23 to 26s G |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: C Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Needle Point Number | No Needle Included |
|---|---|
| Product Type | Gastight Syringe |
| Connection Type | ChemSeal |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing volumes from 100μL up to 100mL |
| Autoclavable | Autoclavable |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: DX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| For Use With (Equipment) | Microlab 500 Diluters/Dispensers |
| Product Type | Gastight Syringe |
| Connection Type | Luer Lock |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
Hamilton™ Syringe Guide for Microliter™ and Gaslight™ Syringes
Designed to work with 700/7000 series MICROLITER syringes and 1700 series GASTIGHT syringes
| Product Type | Syringe Guide |
|---|
Hamilton™ Metal Hub Side Port Needles (Luer Lock)
Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. Needles are 304 stainless steel (sst.). Standard needle length is 2 in. (51mm). Custom needle lengths and point styles are available.
| For Use With (Equipment) | TLL Syringes and LT or TLL Connectors |
|---|---|
| Product Type | Replacement Needle |
| Needle Point Style | Cone with Side Port |
| Material | Nickel-plated Brass (Hub),Stainless Steel |
| Length (English) Needle | 2 in. |
| Autoclavable | Autoclavable |
Hamilton™ 700 and 1700 Series Gastight™ and Microliter™ Digital Syringes: N Termination
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
| Accuracy | ±0.5% |
|---|---|
| Length (Metric) | 51 mm |
| Length (English) | 2 in. |
| Quantity | Ea. |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: RN Termination
Syringes have built-in Chaney Adapters
Hamilton™ 1800 Series Gastight™ Fixed-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
| Needle Point Number | 2 |
|---|---|
| Quantity | 1/Pk. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Type | Gastight, Cemented Needle |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | 2 |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ Microliter™ and Gastight™ Syringes: Model 75 for Agilent 7673, 7683, 7693 and 6850 ALS GC
Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers
| Length (Metric) | 43 mm |
|---|---|
| For Use With (Equipment) | Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers |
| Product Type | Microliter Syringe |
| Volume (Metric) | 5 μL |
| Length (English) | 1.7 in. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
| Length (English) Needle | 1.71 in. |
| Min. Temperature (Metric) | 10°C |
| Max. Pressure | 2000 psi |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: CX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| Product Type | Gastight Syringe |
| Diameter (Metric) Outer | 7.75 mm |
| Connection Type | ChemSeal |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.305 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | For dispensing volumes from 100μL up to 100mL |
| Autoclavable | Autoclavable |